The Building

Great Suffolk Yards is a mix of new building contemporary office space and a sensitive restoration of the original warehouse positioned around a cobbled central courtyard at the heart of the scheme

Retaining much of its industrial heritage, character and proportions, the accomodation features exposed finishes including concrete ceilings with exposed air conditioning, multiple balconies and four roof terraces as well as secure cycle parking for 100 bicycles, showers and locker facilities. The perfect new space for a modern and dynamic workforce.

Interior
Exterior
360 View
Schedule of Areas
Floorplans
Floor Available Space Terrace
Fifth Floor1,178 sq ft.
Third Floor3,994 sq ft.150 sq ft.
First Floor8,413 sq ft.
TOTALOffice:
13,585 sq ft.
Terrace:
699 sq ft.
B
G
1
2
3
4
5
Download

Finished Ceiling Heights

Engineering Building (Typical Floor)
2.95m (to exposed soffit)

The Works Building (Typical Floor)
2.85m (to exposed soffit)

The Sea Building (Typical Floor)
2.95m – 3.7m (to exposed soffit)

The Ground Floor
3.8m – 4.3m (to exposed soffit)

RAISED FLOORS

100mm overall

LOADINGS

Ground floor: 5.0 kN/m2
Upper floors: 2.5 + 1 kN/m2
Plant space: 3.0 kN/m2

Occupational Densities

Building services: 1:8m2 NIA
WCs: 1:8m2 NIA
Lifts & Access: 1:8m2 NIA
Escape: 1:6m2 NIA

Vertical Transportation

Three new 8 person passenger lifts accessing the Engineering & Works Buildings

One new 8 person passenger lift accessing the Sea Building

One new service platform lift accessed from Pickwick Street for cycle & refuse access to the basement floor level

Heating & Cooling

VRF system and fresh air ventilation typically via ceiling mounted fan coil units. Internal design temperature based on 23 C+2 summer and 21 C+2 winter

Low level perimeter VRF fan coil units with high level ventilation only in reduced floor to ceiling height zones

VENTILATION

14 l/s per person (NIA)

Small Power

Allowance of 25W/m2

LIGHTING

Office lighting to achieve 400 lux

Direct/indirect LED luminaires giving diffused light levels and complying with the design intent of CIBSE LG7

Maximum energy use as per BCO guidelines: 10 W/m2

Presence detection and daylight dimming control

Cycle Facilities

110 secure cycle spaces (double stacked) plus ground floor external cycle spaces

11 showers plus 3 associated WCs at basement changing

Sustainability

BREEAM New Build “Excellent”
BREEAM Refurbishment “Very Good”
EPC A Rating

Amenity

Cobbled (brick paver) courtyard at ground floor

Tiling on balconies and terraces at 2nd, 3rd, 4th and 5th floor with metal balustades and/or parapet balustrades

Bio diverse green roofs on multiple roofs

Tenant Plant

Space available for tenant plant at basement and roof, subject to availability